Glo-Protek HB Tank Lining Coating
Glo-Protek HB Tank Lining Coating is a two pack high build epoxy polyamine adduct cured tank lining paint system. This product is self priming epoxy coating designed to use tank lining for the storage of fresh & salt water, brine, sweet & sour crude, other refined petroleum products & solvents It has excellent resistance against highly corrosive & humid atmosphere
TECHNICAL DATA :
Colour | White, Grey ( Dark and Light) |
---|---|
Finish | Matt to Eggshell |
Volume Solids | 62 ± 3 % |
DFT / Coat | 75-150 μ |
Theoretical Coverage / Coat | 4.3 – 8.6 m² / ltr. |
Type | Two Pack |
Mixing Ratio | By Volume |
Component A | 4 parts |
Component B | 1 parts |
Induction Time | 0 – 40 Mins |
Pot life | 2 – 3 hrs at 30°C |
Curing Mechanism | Solvent release and chemical reaction between two components. |
Flash point | Component A : Above 25°C Component B : Above 25°C |
Drying Time (30°C) | Surface Dry - 2 – 3 Hrs Hard Dry - 16 – 18 Hrs Full Cure - 7 Days |
Recoating Time | Min : 18 hrs Max. : 5 days provided surface is dry, clean & free from any contaminants. After max. over coating interval the the surface should be roughened prior to the application f subsequent coat. |
Cure for immersion | 7 days |
Thinner | Epoxy Thinner |
Thinner Consumption | Conventional spray 20 - 40% & Brush 10 - 15% |
Details of Application
Applied over : Blasted cleaned steel
Application Method : Brush / Conventional spray / Airless spray.
Shelf Life : 12 months under normal storage conditions in original containers at 30°C
Pack Size : 20 ltrs.
Surface Preparation
Before applying the piant, all surfaces must be clean, dry and free from oil, grease and other contaminants.. Blast cleaning to Sa 2.5 of Swedish International Standard . In case of aged Epoxy Primer , the surface Should be sufficiently roughened prior to painting.
Application Instruction
Stir the comp. A and comp. B separately. If settling is observed in the comp. A, loosen the settled material and mix it with the help of pneumatic stirrer. Mix the comp. B gradually to the comp. A in the specified ratio under continuous stirring till homogeneous. Use epoxy thinner as specified.
Environmental Condition
Surface temperature must be 3°C above the dew point to prevent condensation.
Temperature
Air 5 - 40°C
Surface 5 - 50°C
Relative Humidity 5 – 80%
Special Notes
Thinner consumption may vary depending upon site conditions. Practical covering capacity depends on application techniques, ambient conditions, wastage, surface condition etc.
Health & Safety